WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "13a4c4f4-a17c-4dc7-8f33-c3285ac3ccea"}, "_deposit": {"created_by": 19, "id": "12599", "owners": [19], "pid": {"revision_id": 0, "type": "depid", "value": "12599"}, "status": "published"}, "_oai": {"id": "oai:asahi-u.repo.nii.ac.jp:00012599", "sets": ["123"]}, "author_link": ["15738"], "item_10_creator_30": {"attribute_name": "教員氏名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "櫻井, 学"}], "nameIdentifiers": [{"nameIdentifier": "15738", "nameIdentifierScheme": "WEKO"}]}]}, "item_10_date_36": {"attribute_name": "発行又は発表の年月", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2020-01"}]}, "item_10_textarea_29": {"attribute_name": "業績分類", "attribute_value_mlt": [{"subitem_textarea_value": "学術論文"}]}, "item_10_textarea_31": {"attribute_name": "発行、発表雑誌等、又は発表学会等の名称", "attribute_value_mlt": [{"subitem_textarea_value": "日本歯科麻酔学会雑誌"}]}, "item_10_textarea_32": {"attribute_name": "巻", "attribute_value_mlt": [{"subitem_textarea_value": "48"}]}, "item_10_textarea_33": {"attribute_name": "号", "attribute_value_mlt": [{"subitem_textarea_value": "1"}]}, "item_10_textarea_34": {"attribute_name": "掲載ページ", "attribute_value_mlt": [{"subitem_textarea_value": "4-6"}]}, "item_10_textarea_35": {"attribute_name": "単著、共著の別", "attribute_value_mlt": [{"subitem_textarea_value": "共著"}]}, "item_10_textarea_42": {"attribute_name": "概要", "attribute_value_mlt": [{"subitem_textarea_value": "症例は14歳の女児,知的能力障害,自閉症,未診断の側彎症を有していた.Portex®気管チューブ6.0mmを挿管したが,SpO2の低下,気道内圧の上昇を認めた.気管支挿管を疑い,Microcuff®気管チューブ6.0mmを再挿管した.この患者では声門から気管分岐部までが短いことが推測された.Microcuff®気管チューブは他の気管チューブと比較してデプスマークからの長さが短いため,側彎症患者の麻酔管理に有効である可能性が示唆された"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "other", "resourceuri": "http://purl.org/coar/resource_type/c_1843"}]}, "item_title": "アナフィラキシーの原因物質の特定に好塩基球活性化試験が 有用であった1症例", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "アナフィラキシーの原因物質の特定に好塩基球活性化試験が 有用であった1症例"}]}, "item_type_id": "10", "owner": "19", "path": ["123"], "permalink_uri": "https://asahi-u.repo.nii.ac.jp/records/12599", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-07-29"}, "publish_date": "2020-07-29", "publish_status": "0", "recid": "12599", "relation": {}, "relation_version_is_last": true, "title": ["アナフィラキシーの原因物質の特定に好塩基球活性化試験が 有用であった1症例"], "weko_shared_id": -1}
アナフィラキシーの原因物質の特定に好塩基球活性化試験が 有用であった1症例
https://asahi-u.repo.nii.ac.jp/records/12599
https://asahi-u.repo.nii.ac.jp/records/125991ee0e233-0fee-4aa6-86ec-6e9eb0652bc6
Item type | 朝日大学 教育・研究業績(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-07-29 | |||||
タイトル | ||||||
タイトル | アナフィラキシーの原因物質の特定に好塩基球活性化試験が 有用であった1症例 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_1843 | |||||
資源タイプ | other | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
業績分類 | ||||||
値 | 学術論文 | |||||
教員氏名 |
櫻井, 学
× 櫻井, 学 |
|||||
発行、発表雑誌等、又は発表学会等の名称 | ||||||
値 | 日本歯科麻酔学会雑誌 | |||||
巻 | ||||||
値 | 48 | |||||
号 | ||||||
値 | 1 | |||||
掲載ページ | ||||||
値 | 4-6 | |||||
単著、共著の別 | ||||||
値 | 共著 | |||||
発行又は発表の年月 | ||||||
日付 | 2020-01 | |||||
概要 | ||||||
値 | 症例は14歳の女児,知的能力障害,自閉症,未診断の側彎症を有していた.Portex®気管チューブ6.0mmを挿管したが,SpO2の低下,気道内圧の上昇を認めた.気管支挿管を疑い,Microcuff®気管チューブ6.0mmを再挿管した.この患者では声門から気管分岐部までが短いことが推測された.Microcuff®気管チューブは他の気管チューブと比較してデプスマークからの長さが短いため,側彎症患者の麻酔管理に有効である可能性が示唆された |