{"created":"2023-06-23T12:19:22.583226+00:00","id":10296,"links":{},"metadata":{"_buckets":{"deposit":"7ed89b37-a411-464e-b410-8e082b8ecd29"},"_deposit":{"created_by":19,"id":"10296","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"10296"},"status":"published"},"_oai":{"id":"oai:asahi-u.repo.nii.ac.jp:00010296","sets":["64:123"]},"author_link":["13770"],"item_10_creator_30":{"attribute_name":"教員氏名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"後藤, 隆志"}],"nameIdentifiers":[{"nameIdentifier":"13770","nameIdentifierScheme":"WEKO"}]}]},"item_10_date_36":{"attribute_name":"発行又は発表の年月","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-10-05"}]},"item_10_textarea_29":{"attribute_name":"業績分類","attribute_value_mlt":[{"subitem_textarea_value":"学会発表"}]},"item_10_textarea_31":{"attribute_name":"発行、発表雑誌等、又は発表学会等の名称","attribute_value_mlt":[{"subitem_textarea_value":"15th International dental congress on anesthesia, sedation and pain control"}]},"item_10_textarea_35":{"attribute_name":"単著、共著の別","attribute_value_mlt":[{"subitem_textarea_value":"共同"}]},"item_10_textarea_42":{"attribute_name":"概要","attribute_value_mlt":[{"subitem_textarea_value":"パルスオキシメータの装着部位の違いがSpO2の測定時間に及ぼす影響について検討を行った。健康成人男性ボランティア10名を対象とした。パルスオキシメータは前額部、両耳、両手指、両趾指の計7箇所に装着した。静脈内鎮静法中の気道閉塞を最も早く反映したのは前額部と手指のセンサーであった。耳のセンサーはSpO2の低下を過小評価している可能性があるため、静脈内鎮静法中の酸素化の指標としては適していないと考えらえる。"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"other","resourceuri":"http://purl.org/coar/resource_type/c_1843"}]},"item_title":"The effects of different pulse oximeter application sites on blood oxygen saturation measurements during intravenous sedation","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The effects of different pulse oximeter application sites on blood oxygen saturation measurements during intravenous sedation"}]},"item_type_id":"10","owner":"19","path":["123"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-01-23"},"publish_date":"2019-01-23","publish_status":"0","recid":"10296","relation_version_is_last":true,"title":["The effects of different pulse oximeter application sites on blood oxygen saturation measurements during intravenous sedation"],"weko_creator_id":"19","weko_shared_id":-1},"updated":"2023-06-23T13:33:58.972164+00:00"}