{"created":"2023-06-23T12:22:00.288504+00:00","id":13787,"links":{},"metadata":{"_buckets":{"deposit":"dd58aa3b-71f3-4ef9-ab91-b3d1ad8bdaec"},"_deposit":{"created_by":21,"id":"13787","owners":[21],"pid":{"revision_id":0,"type":"depid","value":"13787"},"status":"published"},"_oai":{"id":"oai:asahi-u.repo.nii.ac.jp:00013787","sets":["46:190:419"]},"author_link":["4840","4376","4372","4833","4567","4838","4571","310","3955","4835"],"item_10002_biblio_info_77":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-02-20","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"266","bibliographicPageStart":"258","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"岐阜歯科学会雑誌"},{"bibliographic_title":"The journal of Gifu Dental Society","bibliographic_titleLang":"en"}]}]},"item_10002_description_80":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"粘膜調整材のプラークコントロールに対して電解水が応用できるかどうかについて検討した。実験には市販5種類の粘膜調整材を用いた。粘膜調整材を厚さ1mmのアクリリック板に表装し、電解水(強酸性水、強アルカリ水)、酸化型義歯洗浄剤および軟質レジン専用義歯洗浄剤に14日間浸漬した。粘膜調整材のゴム硬さをマイクロゴム硬度計により測定開始から5分間測定し、測定初期の値(初期値)、測定から5分後の値(5分値)を求めた。初期値および5分値から応力緩和の大きさを求めた。ゴム硬さは浸積1日後、3日後、7日後、14日後に測定した。また、同時期に表面粗さ(Ra)を測定した。酸化型義歯洗浄剤は粘弾性および表面性状への影響が大きかった。しかし、電解水は蒸留水や軟質レジン専用義歯洗浄剤との差はなかった。これらの結果から、電解水は粘膜調整材の清掃へ応用可能であることが示唆された。","subitem_description_type":"Abstract"}]},"item_10002_description_81":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"We investigated whether electrolyzed water can be applied to plaque control of tissue conditioner or not. Five commercially-available tissue conditioners relined to acrylic plates were immersed in electrolyzed water and 3 types of denture cleaner for 14 days. The rubber hardness of the tissue conditioners was measured using a micro rubber hardness tester over a 5-minute measurement period. The value just after the start of measurement (Initial value) and the value 5 minutes from the start of measurement (5 minutes value) was measured. The stress relaxation value was calculated by initial value and 5-minute value. Rubber hardness and surface roughness were measured after 1 day. 3 days, 7 days and 14 days of immersion. The electrolyzed water had little effect on the rubber hardness of the tissue conditioner in most tissue conditioners compared to the denture cleaners. The surface roughness of the tissue conditioner was not affected by immersion into the electrolyzed water. These results suggest that the electrolyzed water can be applied to plaque control of tissue conditioner.","subitem_description_type":"Other"}]},"item_10002_full_name_75":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"4571","nameIdentifierScheme":"WEKO"}],"names":[{"name":"SAKAI, MAKOTO"}]},{"nameIdentifiers":[{"nameIdentifier":"4838","nameIdentifierScheme":"WEKO"}],"names":[{"name":"SHIMOMURA, TAKUYA"}]},{"nameIdentifiers":[{"nameIdentifier":"4840","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KISHII, JIRO"}]},{"nameIdentifiers":[{"nameIdentifier":"3955","nameIdentifierScheme":"WEKO"}],"names":[{"name":"YAMAUCHI, MUTSUO"}]},{"nameIdentifiers":[{"nameIdentifier":"4376","nameIdentifierScheme":"WEKO"}],"names":[{"name":"NAGASAWA, TOORU"}]}]},"item_10002_heading_98":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"原著","subitem_heading_language":"ja"},{"subitem_heading_banner_headline":"ORIGINAL ARTICLES","subitem_heading_language":"en"}]},"item_10002_radio_89":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_radio_item":"application/pdf"}]},"item_10002_relation_85":{"attribute_name":"論文ID(NAID)","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"110000051304","subitem_relation_type_select":"NAID"}}]},"item_10002_source_id_82":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03850072","subitem_source_identifier_type":"ISSN"}]},"item_10002_source_id_84":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00053070","subitem_source_identifier_type":"NCID"}]},"item_10002_textarea_76":{"attribute_name":"所属","attribute_value_mlt":[{"subitem_textarea_value":"朝日大学歯学部歯科補綴学講座\nDepartment of Prosthodontics, Asahi University School of Dentistry"},{"subitem_textarea_value":"朝日大学歯学部歯科補綴学講座\nDepartment of Prosthodontics, Asahi University School of Dentistry"},{"subitem_textarea_value":"朝日大学歯学部歯科補綴学講座\nDepartment of Prosthodontics, Asahi University School of Dentistry"},{"subitem_textarea_value":"朝日大学歯科臨床研究所附属歯科診療所\nDental Clinic, Post-doctoral Institute of Clinical Dentistry, Asahi University"},{"subitem_textarea_value":"朝日大学歯学部歯科補綴学講座\nDepartment of Prosthodontics, Asahi University School of Dentistry"}]},"item_10002_version_type_95":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"堺, 誠"}],"nameIdentifiers":[{"nameIdentifier":"4567","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000002269961","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000002269961"},{"nameIdentifier":"10225774","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=10225774"}]},{"creatorNames":[{"creatorName":"下村, 卓也"}],"nameIdentifiers":[{"nameIdentifier":"4833","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000002270030","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000002270030"}]},{"creatorNames":[{"creatorName":"岸井, 次郎"}],"nameIdentifiers":[{"nameIdentifier":"4835","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000002270031","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000002270031"}]},{"creatorAffiliations":[{"affiliationNameIdentifiers":[{"affiliationNameIdentifier":"33703","affiliationNameIdentifierScheme":"kakenhi","affiliationNameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=33703"}],"affiliationNames":[{"affiliationName":"朝日大学歯学部","affiliationNameLang":"ja"}]}],"creatorNames":[{"creatorName":"山内, 六男","creatorNameLang":"ja"},{"creatorName":"YAMAUCHI, MUTSUO","creatorNameLang":"en"}],"familyNames":[{"familyName":"山内","familyNameLang":"ja"},{"familyName":"YAMAUCHI","familyNameLang":"en"}],"givenNames":[{"givenName":"六男","givenNameLang":"ja"},{"givenName":"MUTSUO","givenNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"310","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000002269862","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000002269862"}]},{"creatorNames":[{"creatorName":"長澤, 亨"}],"nameIdentifiers":[{"nameIdentifier":"4372","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"9000254875198","nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000254875198"},{"nameIdentifier":"20034168","nameIdentifierScheme":"e-Rad","nameIdentifierURI":"https://kaken.nii.ac.jp/ja/search/?qm=20034168"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-02-05"}],"displaytype":"detail","filename":"gifushika293_258266_2003.pdf","filesize":[{"value":"786.4 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"gifushika293_258266_2003","url":"https://asahi-u.repo.nii.ac.jp/record/13787/files/gifushika293_258266_2003.pdf"},"version_id":"29c486d2-bb9d-4fab-b748-ff6d327aee34"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"粘膜調整材","subitem_subject_scheme":"Other"},{"subitem_subject":"電解水","subitem_subject_scheme":"Other"},{"subitem_subject":"義歯洗浄剤","subitem_subject_scheme":"Other"},{"subitem_subject":"ゴム硬さ","subitem_subject_scheme":"Other"},{"subitem_subject":"表面性状","subitem_subject_scheme":"Other"},{"subitem_subject":"Tissue conditioner","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electrolyzed water","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Denture cleaner","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Rubber hardness","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Surface condition","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"電解水の粘膜調整材への影響","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電解水の粘膜調整材への影響"},{"subitem_title":"Effect of Electrolyzed Water on Tissue Conditioner","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"21","path":["419"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-05"},"publish_date":"2022-02-05","publish_status":"0","recid":"13787","relation_version_is_last":true,"title":["電解水の粘膜調整材への影響"],"weko_creator_id":"21","weko_shared_id":-1},"updated":"2024-02-16T07:38:46.890647+00:00"}