WEKO3
インデックスリンク
アイテム
Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy.
https://asahi-u.repo.nii.ac.jp/records/9142
https://asahi-u.repo.nii.ac.jp/records/91427cd26ff2-0797-4358-a686-5ffa6be2aa9c
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-01-27 | |||||
タイトル | ||||||
タイトル | Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy. | |||||
タイトル | ||||||
タイトル | Comparison of urethral diameters for calculating the urethral dose after permanent prostate brachytherapy. | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Brachytherapy | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Contrast Media | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Gadolinium DTPA | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Humans | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Magnetic Resonance Imaging | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Male | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Prospective Studies | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Prostatic Neoplasms | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Radiotherapy Dosage | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Tomography, X-Ray Computed | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Ultrasonography, Interventional | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Urethra | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tanaka, Osamu
× Tanaka, Osamu× Hayashi, Shinya× Matsuo, Masayuki× Nakano, Masahiro× Kubota, Yasuaki× Maeda, Sunaho× Ohtakara, Kazuhiro× Deguchi, Takashi× Hoshi, Hiroaki |
|||||
所属 | ||||||
Department of Radiology, Gifu University School of Medicine Division of Radiation Oncology, Gifu University Hospital |
||||||
所属 | ||||||
Department of Radiology, Gifu University School of Medicine Division of Radiation Oncology, Gifu University Hospital |
||||||
所属 | ||||||
Department of Radiology, Gifu University School of Medicine Division of Radiation Oncology, Gifu University Hospital |
||||||
所属 | ||||||
Department of Urology, Gifu University School of Medicine | ||||||
所属 | ||||||
Department of Urology, Gifu University School of Medicine | ||||||
所属 | ||||||
Department of Radiology, Gifu University School of Medicine Division of Radiation Oncology, Gifu University Hospital |
||||||
所属 | ||||||
Department of Radiology, Gifu University School of Medicine Division of Radiation Oncology, Gifu University Hospital |
||||||
所属 | ||||||
Department of Urology, Gifu University School of Medicine | ||||||
所属 | ||||||
Department of Radiology, Gifu University School of Medicine | ||||||
書誌情報 |
en : Radiation medicine 巻 25, 号 7, p. 329-334, 発行日 2007-08-01 |
|||||
出版者 | ||||||
Springer | ||||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0288-2043 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 17705002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | info:doi/10.1007/s11604-007-0146-2 | |||||
フォーマット | ||||||
内容記述タイプ | Other | |||||
内容記述 | application/pdf | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://link.springer.com/article/10.1007%2Fs11604-007-0146-2 | |||||
関連名称 | 出版社版(Springer) |