{"_buckets": {"deposit": "868e961a-0583-4a50-a304-bf0c969f85a1"}, "_deposit": {"created_by": 21, "id": "12201", "owners": [21], "pid": {"revision_id": 0, "type": "depid", "value": "12201"}, "status": "published"}, "_oai": {"id": "oai:asahi-u.repo.nii.ac.jp:00012201", "sets": ["448"]}, "author_link": ["4176", "328", "14131", "3955", "15394", "4197"], "item_10002_biblio_info_77": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "126", "bibliographicPageStart": "123", "bibliographicVolumeNumber": "46", "bibliographic_titles": [{"bibliographic_title": "岐阜歯科学会雑誌"}, {"bibliographic_title": "The Journal of Gifu Dental Society", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_80": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We examined the reproducibility of measurement values obtained using the recently released Dental Prescale II system (50H, GC) and analysis software (Bite Force Analyzer, GC). One adult male volunteer with normal occlusion was asked to bite down for 3 s with the Prescale II in situ to produce the sample. Occlusal contact area, mean occlusal pressure, and occlusal force were measured. The measurements were then analyzed 5 times each under the following conditions: 1) with the sample placed on the scanner (reference condition); 2) after removing and then replacing the sample on the scanner (repositioned); 3) after automated trimming (adjusted); 4) after manual trimming on the screen (manually adjusted); and 5) after the sample was stored for 2 days indoors (day 2) or 3 days indoors (day 3). Statistical analysis was performed using one-way analysis of variance with Bonferroni post hoc analysis. The coefficient of variation (CV) was also determined. Measurement values for occlusal contact area were significantly lower under the reference condition than under the repositioned, adjusted, manually adjusted, and day 3 conditions. Mean occlusal pressure was significantly higher under all conditions compared with the reference condition. Occlusal force was significantly lower under the repositioned, adjusted, and manually adjusted conditions compared with the reference condition but was significantly higher under the day 2 condition. CV values were 0.71-4.48 for occlusal contact area, 0.46-1.23 for mean occlusal pressure, and 0.28-1.05 for occlusal force. These results indicate high reliability of the Dental Prescale II system and occlusal force analysis software.", "subitem_description_type": "Abstract"}]}, "item_10002_heading_98": {"attribute_name": "見出し", "attribute_value_mlt": [{"subitem_heading_banner_headline": "原著", "subitem_heading_language": "ja"}, {"subitem_heading_banner_headline": "ORIGINAL ARTICLE", "subitem_heading_language": "en"}]}, "item_10002_radio_89": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_radio_item": "application/pdf"}]}, "item_10002_select_90": {"attribute_name": "情報源", "attribute_value_mlt": [{"subitem_select_item": "CiNii"}]}, "item_10002_source_id_82": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2433-0191", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_textarea_76": {"attribute_name": "所属", "attribute_value_mlt": [{"subitem_textarea_value": "Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry"}, {"subitem_textarea_value": "Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry"}, {"subitem_textarea_value": "Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry"}, {"subitem_textarea_value": "Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry"}, {"subitem_textarea_value": "Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry"}, {"subitem_textarea_value": "Asahi University"}]}, "item_10002_textarea_78": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_textarea_value": "岐阜歯科学会"}]}, "item_10002_version_type_95": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ADACHI, KOTONO"}], "nameIdentifiers": [{"nameIdentifier": "15394", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Hiroaki"}], "nameIdentifiers": [{"nameIdentifier": "4176", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Watanabe, Ryou"}], "nameIdentifiers": [{"nameIdentifier": "14131", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "IWAHORI, MASATOSHI"}], "nameIdentifiers": [{"nameIdentifier": "4197", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MIYAO, MOTONOBU"}], "nameIdentifiers": [{"nameIdentifier": "328", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YAMAUCHI, MUTSUO"}], "nameIdentifiers": [{"nameIdentifier": "3955", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-03-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "gifushika463_123126_2020.pdf", "filesize": [{"value": "958.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 958900.0, "url": {"label": "gifushika463_123126_2020", "url": "https://asahi-u.repo.nii.ac.jp/record/12201/files/gifushika463_123126_2020.pdf"}, "version_id": "213d5e88-937e-45f9-97de-b0a1046980e0"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Dental Prescale II", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "analysis software", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reliability", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "occlusion", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements"}, {"subitem_title": "Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "21", "path": ["448"], "permalink_uri": "https://asahi-u.repo.nii.ac.jp/records/12201", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-03-28"}, "publish_date": "2020-03-28", "publish_status": "0", "recid": "12201", "relation": {}, "relation_version_is_last": true, "title": ["Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements"], "weko_shared_id": -1}
Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements
https://asahi-u.repo.nii.ac.jp/records/12201
https://asahi-u.repo.nii.ac.jp/records/1220160975dfc-70bf-48f1-b773-4c0d920d4335
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-03-28 | |||||
タイトル | ||||||
タイトル | Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Reproducibility of the Newly Developed Dental Prescale II System and Bite Force Analyzer for Occlusal Measurements | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Dental Prescale II | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | analysis software | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | reliability | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | occlusion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
ADACHI, KOTONO
× ADACHI, KOTONO× Yamamoto, Hiroaki× Watanabe, Ryou× IWAHORI, MASATOSHI× MIYAO, MOTONOBU× YAMAUCHI, MUTSUO |
|||||
所属 | ||||||
値 | Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry | |||||
所属 | ||||||
値 | Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry | |||||
所属 | ||||||
値 | Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry | |||||
所属 | ||||||
値 | Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry | |||||
所属 | ||||||
値 | Department of Prosthodontics, Division of Oral Functional Sciences and Rehabilitation, Asahi University School of Dentistry | |||||
所属 | ||||||
値 | Asahi University | |||||
書誌情報 |
岐阜歯科学会雑誌 en : The Journal of Gifu Dental Society 巻 46, 号 3, p. 123-126, 発行日 2020-02 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We examined the reproducibility of measurement values obtained using the recently released Dental Prescale II system (50H, GC) and analysis software (Bite Force Analyzer, GC). One adult male volunteer with normal occlusion was asked to bite down for 3 s with the Prescale II in situ to produce the sample. Occlusal contact area, mean occlusal pressure, and occlusal force were measured. The measurements were then analyzed 5 times each under the following conditions: 1) with the sample placed on the scanner (reference condition); 2) after removing and then replacing the sample on the scanner (repositioned); 3) after automated trimming (adjusted); 4) after manual trimming on the screen (manually adjusted); and 5) after the sample was stored for 2 days indoors (day 2) or 3 days indoors (day 3). Statistical analysis was performed using one-way analysis of variance with Bonferroni post hoc analysis. The coefficient of variation (CV) was also determined. Measurement values for occlusal contact area were significantly lower under the reference condition than under the repositioned, adjusted, manually adjusted, and day 3 conditions. Mean occlusal pressure was significantly higher under all conditions compared with the reference condition. Occlusal force was significantly lower under the repositioned, adjusted, and manually adjusted conditions compared with the reference condition but was significantly higher under the day 2 condition. CV values were 0.71-4.48 for occlusal contact area, 0.46-1.23 for mean occlusal pressure, and 0.28-1.05 for occlusal force. These results indicate high reliability of the Dental Prescale II system and occlusal force analysis software. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2433-0191 | |||||
フォーマット | ||||||
値 | application/pdf | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
見出し | ||||||
大見出し | 原著 | |||||
言語 | ja | |||||
見出し | ||||||
大見出し | ORIGINAL ARTICLE | |||||
言語 | en |